Operating unit for an air conditioner with an Israeli socket

Model: EN-AMAC-PB

Air conditioning operating unit, without automatic return (start / stop), microprocessor controlled.

The unit includes:

  • 3-5 minutes activation delay option that can be implemented on site by the installer.
  • 3-5 minutes re-activation delay option including memory which is counted from the time of the power failure, to prevent unnecessary waiting.
  • “AC disconnection timer” option after several working hours, 2, 3, 4, or 6 hours, that can be implemented on site by the installer.
  • You may start the “air conditioner disconnection timer” during the AC unit’s operation, without disconnecting the air conditioner.
  • Effective protection against momentary power outages, AC disconnection’s response speed is shorter than 0.1 seconds, in accordance with the Israeli standards institution’s specification 198 requirements.
  • Effective protection against continuous voltage drops and the AC unit’s disconnection at a 175-179.5 voltage, in accordance with the Israeli standards institution’s specification 198 requirements.
  • Effective protection against continuous voltage bursts and the AC unit’s disconnection at a voltage above 253 volts.
  • Command entry for the AC unit’s remote disconnection, from the EN-AM-2020 digital saving system or from a building control system.
  • Israeli socket or British socket, or without a socket for direct connection to the air conditioner.

Technical features:

  • Working voltage 230VAC 50Hz.
  • Ambient temperature – (-10 ° C) – (+ 45 ° C).
  • Bipolar disconnection, in accordance with the electricity regulations.
  • Working current per unit with an Israeli or British socket – P.F ≥ 0.92 16A.
  • Working current per unit without a socket – P.F ≥ 0.92 20A.
  • Structure – a thermoplastic, self-extinguishing material, e.g. polycarbonate.
  • The unit meets the requirements of T.I. 32, T.I. 33, T.I. 60669-2-1 Israeli standards institution’s specification 198 requirements.

Installation:

  • Units can be ordered for installation in the following methods – Under plaster, on plaster or in a gypsum drywall